Search In this Thesis
   Search In this Thesis  
العنوان
A Comparative in vitro study for evaluation of two types of frictionless brackets and one type of conventional bracket /
المؤلف
Mansour, Mohammed Moustafa.
هيئة الاعداد
باحث / Mohammed Moustafa Mansour
مشرف / Amany Hassan
مشرف / Eman Mohieeldin
الموضوع
Orthodontic Brackets.
تاريخ النشر
2011.
عدد الصفحات
vii, 94, [2] Leaves :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Orthodontics
تاريخ الإجازة
1/1/2011
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Orthodontics
الفهرس
Only 14 pages are availabe for public view

from 51

from 51

Abstract

The objective of this study was to evaluate and compare, the kinetic frictional force between two recent generation of frictionless brackets (fx SWLF and Damon 3MX), and one conventional bracket (Mini 2000). Seventy-two maxillary right stainless steel canine brackets, with slot size 0.022x0.028- inch, were used. The brackets were equally divided into three groups; Group І for the fx SWLF brackets, group ІІ for the Damon 3 MX (self-ligated) brackets, while group ІІІ was for Mini 2000 (conventional) brackets. Kinetic frictional resistance was measured in each group using three wires; 0.018, 0.016×0.022, and 0.018×0.025 inch st st wires.